Manufacturers
-
Yale 7100 Series Latch Assy 60-7000-0419-048
Yale 7100 Series Latch Assembly
This latch assembly is used on non fire rated doors, meaning panic devices that you can not dog open with the allen key or key cylinder. Non fire rated doors are usually exterior doors.
Yale Part # 60-7000-0419-048
Note the position of the Hub for this Assembly is the 7100
G6070000419048 -
Cal Royal 6600 Rim Device
The Cal-Royal 6600 Rim Device is a Grade 1 exit device. It is designed for doors that have at least a 4-1/2 inch stile width. The 36 inch device has a 32 inch actual length and can cut down 6" (24 inch actual). The 48 inch device has an actual length of 44 inches and can be cut down 12 inch (34 inch actual). Devices ships with 938 Strike and all the mounting screws.
CR6600- -
Cal Royal 6660 Surface Vertical Road
The Cal-Royal 6660 Surface Vertical Rod Device is a Grade 1 exit device. It is designed for doors that have at least a 3-3/4 inch stile width. The 36 inch device has a 32 inch actual length and can cut down 6" (24 inch actual). The 48 inch device has an actual length of 44 inches and can be cut down 12 inch (34 inch actual). Devices ships with 938 Strike and all the mounting screws.
6660EO -
Cal Royal ESC6600 Escutcheon Lever Trim
The ESC6600 are non handed, with a Grade 1 thru bolted design. It features a clutch mechanism, double heavy duty spring support to prevent sagging and a hardened stell heavy duty spindle. Entrance function, key locks or unlocks lever, operates as a Classroom Function. Ships with mounting screws and a 6-Pin Schlage Mortise Cylinder.
ESC6600- -
Von Duprin 22, 33, And 99 Dogging Shaft 090040
The Von Duprin 22, 33, And 99 Dogging Shaft 090040 is the peice that the hex dogging key would fit into. The shaft is for a 5/32" dog key, but it has to be the long version. The shorter versions will not have enough reach to get all the way into the shaft. This is a very common problem area, the hole that the key fits in is only about 1/4" deep, and if you do not push down on the hex key when locking it open it will round out over time. To remove the shaft, just pull it straight out with a part of channel locks. We reinstalling the new one you might have to bend the ends of the adapter spring 090042 back down. This dogging shaft is for use on all Von Duprin Panic Exit Devices shipped after 1997.
G090040 -
Von Duprin Dogging Hook 090044
The Von Duprin Dogging Hook 090044 is the piece that grabs the push bar mechanism and keeps it in the dogged position. The does wear out, but it takes a long time. This piece is used on the 22, 33A, 35A, 98 and 99 series devices made after 1997. We sell this part individually and it is #5 on the diagram.
G090044 -
Von Duprin 050534 EL Potted Circuit Breaker
The Von Duprin 050534 EL Potted Circuit Breaker measures 5" long by 1-1/4" wide and 7/16" thick including the wires. This piece spikes the current to the solenoid to open the door, then lowers the current to keep the device open. The 050534 has a plug for the two wire input, and a plug for the 3 wire output. This Potted Circuit Breaker is also used on the Doromatic/Falcon Exit Devices, EL1490, EL1590, EL1690, EL1790, and EL2390. We sometimes find the number 101031-00 and 2148 on a sticker.
Old Von Duprin Part # 110741
Von Duprin Part # 050534
Doromatic/Falcon Part # 050534-00G050534 -
Von Duprin 050535 El Solenoid Assy
Von Duprin 050535 El Solenoid Assy-Discontinued. All of our stock is gone, the only way to have your current device work with Electric Latch Retraction would be to up grade to the newer version. The newer version is the QEL or QEL-HD Conversion Kit. Here is a link to the QEL Conversion Kit.
Screws are 1" on center, the cylinder measures 3" long by 1-3/4" diameter. Used on the 33A, 35A, 98 and 99 exit and panic devices. This Solenoid Assembly is also used on the Doromatic/Falcon EL1690, EL1790 and EL2390
We sometimes find the number 971687, along with 4011 VDC 24
Von Duprin Part Number 050535
Doromatic/Falcon Part # 971687-00G050535 -
Von Duprin 2227/3327A/9927 Top Latch 050400
The Von Duprin 050400 Top Latch is used on the 2227, 3327A, 3427A, 9827 and 9927 exit devices. It is used the Fire-Rated along with the standard Panic Devices. The 050400 is sold without the the Mounting Bracket, if you need the Mounting Bracket you can order the 050546, or order the G99VR10 (050091) which will come with the Bracket. This latch is for use on devices shipped after October 1998. This is usually the problem if your bottom rod is dragging on the floor. Includes screws.
Von Duprin Part # 050400
G050400 -
Von Duprin 2227/3327/9927 Bottom Latch 050401
Von Duprin 22, 33, 9927 Bottom latch.
Used to replace the bottom latch on the Von Duprin 2227, 3327A, and 9927 on devices shipped after October 1998.
Includes screws and sometimes the bracket
Von Duprin Part # 050401
G050401 -
Von Duprin ALK Alarm Kit
The Von Duprin ALK Alarm Kit converts the Von Duprin 22, 33A, 35A, 98 and 99 Devices to an alarmed exit device. When you exit the 85 decibel alarm will sound. Powered by a standard 9 volt battery and is controlled by a Mortise Cylinder with a straight cam. When battery is low, the alarm will beep.
Mortise Cylinder NOT included.
Von Duprin Part # 22-ALK, 33A-ALK, 35A-ALK, 98-ALK AND 99-ALK
ALK -
Detex Advantex 40 Series Narrow Stile Rim
The Detex 40 Series rim exit device is a supper heavy duty panic device for use on narrow stile doors. Device features an angled end cap to deflect damage away from the unit. This device is designed for years of trouble free service in high use, high abuse enviroments.
G40REO- -
Command Access PS204 Power Supply
The PS204 power supplies input 110-120VAC and deliver (2) amps @ 24VDC to (4) PTC fused outputs. It also provides (4) solid-state input triggers, protects system relays from shorts, grounds and surges. Its linear design makes it a perfect match for electric locks, motor driven exit devices, electric strikes, and mag locks. Box measures 13 x 15.5 x 5 inches.
PS204 -
Corbin Russwin 650F36-8 ED5200A Active Head
Corbin Russwin ED5200A Active Head
Used on the Corbin Russwin ED5000 Rim Devices, for fire rated doors. For non fire rated doors, order the G650F35-8. A fire rated door is a door were you can NOT use your allen wrench to dog, or lock, the door in the open position during business hours.
Corbin Russwin part # 650F36-8
Rim Cylinder Hub Position for the ED5200A
G650F36-8