Search results for: 'bronz 8 door kick down'
-
Jackson Panic Device Center Case 1085/1095
The Jackson Panic Device Center Case 1085/1095 is for use with the 1085 devices for both and left, and the inactive case of the 1095. Case is easily removed by loosening the two 1/8" Allen screws and one on the bottom. Includes everything in the housing. The distance between the mounting studs on this Case is 6-5/16"
Jackson part # 30-982 Right Hand Body and Arm Assembly
Jackson part # 30-983 Left Hand Body and Arm AssemblyHousing Shown in Aluminum
G1085XX -
Rixson 117 Hinge Set
Application
includes 180 top pivot
Interior Doors
Weight to 300 lbs.*
Door Width up to 3'6"(1067mm)
Handed117 -
Rixson 147 Pivot Set
Exterior or Interior Doors
Weight to 600 lbs.*
Exterior Door Width up to 3'0"(914mm)
Interior Door Width up to 3'6"(1067mm)
Includes 180 Top Pivot
Handed147 -
Ives 7212 Pivot Set
• Handed
• Top, header mount
• Bottom, jamb mount
• Use with 1-3/4" minimum door thickness, with 1/8" bevel in 2"
• Maximum door load 200 pounds
• Vertical adjustment range 3/16", with positive locking7212 -
Rixson 117-1/4 Pivot Set
Application
Interior Doors
Weight to 250 lbs.*
Door Width up to 3'6"(1067mm)
Includes 180 Top Pivot
Handed117-1/4 -
ALREX Door Closer Hinge
The ALREX hinge is a full function hydraulic door closer hinge. It contains all the features of a door closer, closing and latching speed control, power adjustment, and optional hold open feature. They are available in 4, 4.5 and 5 inch (leaf height), and are currently available in Stainless and Black finishes.
Package includes 2 hydraulic closer hinges and one dummy, for a standard 3 x 7 foot door, 100 pound door.
Door Handing:
AX21 -
Jackson 1085 30-1242 / 30-1243 Lever Arms
The Jackson 1085 30-1242 / 30-1243 Lever Arms are for use with the Jackson 1085 Housings, both sides. And the Jackson 1095 Inactive (hinge side) Housings. To determine hand, stand inside and look out the door, what is side is the arm on? If it is on the Right then order Right.
G10852x -
Rixson 119 Intermediate Hinge
• Not load-bearing
• Available 3/4"(19mm) offset only
• Non-ferrous base material
• Used with 117, 117-1/4, 195, UNI closers,
127 closer
• Maintains door alignment
• Furnished with wood and machine screws119 -
Jackson 1095 30-1247 / 30-1248 Lever Arm
The Jackson 1095 30-1247 / 30-1248 Lever Arm. Replacement Lever Arm for the Jackson 1095 Active Housings. This arm will only work on the 1095 Active Case! The difference between this arm and the 1085 arm is the Pin in in the top of the arm. The pin fits into the triangular linkage clip, which actuates the latch bolt. Handing is determined by standing inside and looking out, if the arm in on the right hand side of the door, it is a right hand lever that you would order.
G10955X -
Von Duprin 55 End Case Kit 050196 and 050197
The Von Duprin 55 End Case is the housing on the hinge side of the door. The function of this housing is to lift the cross bar, and support the function of the Active Case. If your housing is on the right side when standing inside looking out, then you would order the Right Hand Case. The package includes the housing, springs and back plate, the arm is not included. The current part number on this part is 050196 and 050197, the old part number is 111931 and 111932.
Other finishes are available upon request.
55R30 -
Rixson 28 Series Door Closer
Center Hung Door Closer
• Available (NHO) non-hold open, or (SHO) selective
hold open. Specify degree (90 or 105°)
• Standard top pivot: 340 included
• Cycolac cement case
• Separate independent valves for closing,
latch and backcheck adjustments
• Built-in positive dead stop prevents door
from swinging beyond desired opening
degree
• Vertical and horizontal door adjustment
• Arm centering adjustment28 -
Dor-o-Matic 1990 Housing and 1090 2090 Inactive Housing DCX
The Dor-o-Matic 1990 Housing and 1090 2090 Inactive Housing DCX has been around since the early 1970's. Although it is now called a Falcon 1990, it is still the same device. This housing is also the inactive housing on the Dor-O-Matic / Falcon 1090 and 2090 panic hardware. The housing includes all of the interior springs, arm, and dogging screw. Housing measures 7-1/2" long by 1-3/16" wide. The center to center distance of the mounting studs is 6-1/4".
LEFT HAND SHOWN IN PICTURE
See diagrams for handing.
Doromatic part #
4270902784 - right hand dark brown
4270902782 - right hand aluminum
4270902785 -right hand black
4270902778- left hand dark brown
4270902776 - left hand aluminum
4270902779- left hand blackG199001 -
Jackson Panic Device 1095 Active Housing
The Jackson Panic Device 1095 Active Housing is the working side of the 1095 panic hardware. The housing comes will all the internal parts, including the latch bolt. The distance between the mounting studs on this case is 6-5/16". Jackson part # 30-988 Right Hand Body, and part # 30-989 Left Hand Body
Left Hand Housing shown in the aluminum finish.
G1095xx -
Rixson 27 Series Door Closer
• Available (NHO) non-hold open,
(SHO) selective
hold open. Specify degree (90, or
105°)
• Standard top pivot: 180 included
• Cycolac cement case
• Separate independent valves for closing,
latch and backcheck adjustments
• Built-in positive dead stop prevents door
from swinging beyond the desired
opening degree
• Vertical door adjustmentWhen Less All Parts is selected only the Cylinder is shipped, just the replacement hydraulic cylinder will be shipped
27-RIX -
Reinforcing Pivot Hinge
The reinforcing pivot hinge is a good way to solve door sag issues. And also be a preventative solutions for future isses with extra heavy or wide doors. The hinges comes in two sizes 4 or 4.5 inches, and two finishes, prime coat and satin chrome. The hinge uses a heavy duty ball-bearing to add extra life. The base metal is steel.
GBB85