  1. Monarch 914KIL-KD Panic Device Lever Trim

    Monarch 914KIL-KD Panic Device Lever Trim

    The 914KIL Lever Trim is for use on the Monarch / Falcon 19 Series.  This lever trim is shipped with a standard Schlage C Keyway, that are keyed different if you are ordering multiple levers.  The key locks and unlocks the Lever handle.

    Monarch Falcon Part # 914KIL-KD

    914KIL-KD-
    As low as $184.25
  2. Monarch 912L Panic Device Lever Trim

    Monarch 912L Panic Device Lever Trim

    The Monarch / Falcon 912L Lever Trim is for use on the Monarch / Falcon 19 Series.  The 912L measures 7-1/4" high by 1-3/4" wide and the mounting plate is 5/8" thick.  We ship these with the Dane Lever, which projects out 2-7/8" in the Classroom function.  On the Classroom function the key locks and unlocks the lever handle, the Key Cylinder is not included.  We offer this Lever Trim in Painted Aluminum, Painted Dark Bronze, and Brushed Satin Nickel.

    Monarch Part # 912L Dane

    G912L-
    As low as $142.38
  3. Von Duprin Panic Device 880NL Trim

    The Von Duprin Panic Device 880NL Trim is for the 88 Series only.   The stanchions welded on the back of the plate line up with the88 device on the interior.  Optional key cylinder locks and unlocks the device, and can be used for dogging the door open.  Plate measures 3" wide by 14-3/16" long, with an 1-5/8" bore for cylinder.

    Von Duprin part # 880NL-R

    Plated Door Finishes

    880NL
    As low as $392.07
  4. Von Duprin Panic Device 880TP Trim

    The Von Duprin Panic Device 880TP Trim is for the 88 series only.  The stanchions welded on the back line up with the 88 device on the interior.  The optional key cylinder locks and unlocks the thumb piece.  The plate measures 3" wide by 14-3/16" long with an 1-5/8" bore hole for cylinder.

    Von Duprin part # 880TP-R

    Plated Door Finishes

    88TP-
    As low as $386.91
  5. Von Duprin Panic Device 880K Trim

    The Von Duprin Panic Device 880K Trim is for use with the 88 series devices only.  Plate measures 3" wide by 14-3/16" long with an 1-5/8" diameter bore for cylinder. Knob projects out 2-3/4".  We do not sell many of these anymore, due to ADA requirements, but they are still available.

    Plated Door Finishes

    88K-
    As low as $346.79
  6. Von Duprin Panic Device 880DT Trim

    The Von Duprin Panic Device 880DT Trim is for 88 Series devices only.  Stanchions welded on the back line up with the device on the interior. The plate measures 3" wide by 14-3/16" long.

    Von Duprin part # 880DT-R

    Plated Door Finishes

    88DT-
    As low as $323.88
  7. Cal Royal Panic Device 2000 Series Lever Trim

    Cal Royal 2000 Series Exit Device Lever Trim

    Non-handed Grade 1 (Clutch Style)
    Cylindrical body hardened steel heavy duty tailpiece. For
    1¾” and 2 ¼” doors. Prefix THI before part # for 2 ¼” door
    thickness. Available for fire and non fire rated rim and
    vertical rod exit devices.
    Rose diameter 3 ½”, lever length 4 ¾”.

    ENTOOL-
    As low as $151.52
  8. Cal Royal Panic Device 2000 Exit Device

    Cal Royal A2200 Series Rim Device

    Grade 1
    Non handed
    3/4" latch bolt throw
    Heavy gauge steel, painted

    Devices available for 32" and 24" wide doors. Please call 1-800-642-2403 for more information

    2000
    As low as $197.75
  9. Cal Royal Panic Device A2200V Exit Device

    Cal Royal A2200V Surface Vertical Rod

    Grade 1
    Non handed-field reversible
    Heavy gauge steel, painted
    4-1/2" minimum stile width

    24" wide x 84" high, and 32" wide and 84" high also available in aluminum only

    2000V
    As low as $304.37
  10. Command Access MLRK1-JAC12 Motorized Latch Retraction for Jackson CRL 1200

    The Command Access MLRK1-JAC12 Motorized Latch Retraction Kit With REX is for use on the Jackson CRL 1285 and 1295 Series Exit Devices. The unit is 24 volt with Standard : 900 mA (Avg Current Peak); 200 mA (Avg Current Hold). The unit requires 18 ga wires. The package includes:  1) Motor Mount with MM5; (1) 50944 Molex Pigtail; (1) 50030 6 Feet Lead with VD Connector; (2) 40124 10-24 x 3/8inch Phillips Screws (Silver); (2) 40125 10-24 x 3/8inch Phillips Screws (Black).

    The MLRK1-JAC12 is a cost-effective and straightforward way to upgrade your Jackson 12, Kawneer 16/17 and PD16 series device to motor-driven latch retraction in the field. UL Listed + 3 Year Warranty.

    MLRK1-JAC12
    $450.00
  11. Sargent 700 ET Retrofit Kit 730-1

    Sargent 700 ET Spindle Kit 730-7

    This Sargent Kit 730-7 includes the spring, spindle and the associated plates. Look under "More Views" for a detailed look of this repair kit. The 730-7 is for 1-3/4" doors.   Shank measures 4-1/4" long, square spindle is 5/16" square.

    Sargent Part # 730-7

    G7301
    $73.34
  12. Jackson 30915J Rod and Case Assembly 7'

    The Jackson Exit Device Rod and Case Assembly is used on 7' doors for the models 1085, 1285 and 2086 devices.

    Jackson part # 30915J

    G108514
    $194.04
  13. Falcon Dor-O-Matic 1690 Auxiliary Package PKG.150

    Rating:
    80%

    The Falcon Dor-O-Matic 1690 Auxiliary Package PKG.150 is one of the installation packages shipped with new devices.   The kit includes the Rod Bearing Bushings (G199003), Traveler Lift Bracket, Retaining Rings (G199004) and 5/32" Dog Key (88R60).

    GPBX169
    $45.58
  14. Sargent 97-0050 Knob Return Spring

    Sargent 97-0050 Knob Return Spring

    This Sargent Knob Return Spring measures 1-1/16" overall length by 3/16" diameter

    Sargent Part # 97-0050

    G970050
    $6.00
  15. Sargent 97-3230 Cylinder Dogging Assembly

    Sargent 97-3230 Cylinder Dogging Assembly

    The Sargent 816 Cylinder Dogging Assembly, also known as the 97-3230, includes the cam that the cylinder dogging tends to wear out.

    Sargent Part # 97-3230

    G973230
    $64.00
  16. Sargent 97-0300 8700 Top Latch Spring

    Sargent 97-0300 8700 Top Latch Spring

    The Sargent 97-0300 8700 Top Latch Spring is used on most of the new and older style Sargent Panic Devices.   The springs measures 1-5/8" overall length.

    Sargent Part # 97-0300

    G970300
    $27.99
  17. Jackson 1095 30-1247 / 30-1248 Lever Arm

    The Jackson 1095 30-1247 / 30-1248 Lever Arm.  Replacement Lever Arm for the Jackson 1095 Active Housings.   This arm will only work on the 1095 Active Case!  The difference between this arm and the 1085 arm is the Pin in in the top of the arm.   The pin fits into the triangular linkage clip, which actuates the latch bolt.  Handing is determined by standing inside and looking out, if the arm in on the right hand side of the door, it is a right hand lever that you would order.

    G10955X
    As low as $49.72
  18. Jackson 1085 30-1242 / 30-1243 Lever Arms

    The Jackson 1085 30-1242 / 30-1243 Lever Arms are for use with the Jackson 1085 Housings, both sides.  And the Jackson 1095 Inactive (hinge side) Housings.  To determine hand, stand inside and look out the door, what is side is the arm on?  If it is on the Right then order Right.

     

    Door Closer Stop Colors

    G10852x
    As low as $49.72
  19. Sargent 700 ET Spindle Kit 730-7

    Sargent 700 ET Spindle Kit 730-7

    This Sargent Kit 730-7 includes the spring, spindle and the associated plates. Look under "More Views" for a detailed look of this repair kit. The 730-7 is for 1-3/4" doors.   Shank measures 4-1/4" long, square spindle is 5/16" square.

    Sargent Part # 730-7

    G7307
    $84.01
  20. Jackson Panic Device 1085 and 1095 Thumb Piece Dogging Pin 30-1117

    The Jackson Panic Device 1085 and 1095 Thumb Piece Dogging Pin 30-1117 is a replacement for the Screw Driver Headed Dogging Pin.  Now instead of using a screw driver you can use the handy thumb piece instead.   The package comes with new set screw, spring, and of course the pin.  Jackson part number 30-1117.

    G108554TP
    $33.34
  21. Sargent 80 Series End Cap Bracket

    Sargent Exit Device 80 Series Bracket

    Used on to hold exit device on door, plastic end cap mounts to it.

    Sargent part # 68-0511

    G80300B
    $60.00
  22. Sargent Exit Device 80 Series Plastic End Cap And Bracket

    Sargent Exit Device 80 Series Plastic End Cap And Bracket

    includes the end cap, bracket and mounting screws. This plastic end cap always breaks. You might want to consider trying the new impact resistant end cap shown in the related products, on the right hand margin of the page.

    Used on the Sargent 80 Series Exit Devices

    Part #'s 68-0561, 68-0511 and 97-0052

    G80300
    $94.01
  23. Sargent 80 Series Metal End Cap And Bracket 565

    Sargent Exit Device 80 Series Metal End Cap And Bracket

    Use this end cap to replace all older versions and plastic end caps. It is much stronger then the orginals, more impact resistant.

    sargent part # 565

    G80300SS-
    As low as $104.29
  24. Dor-O-Matic 1690/1790/2390 Dogging Hex Shaft

    The Dor-O-Matic 1690/1790/2390 Dogging Hex Shaft is the piece that your dog key (allen wrench) fits into the lock the device in the open or dogged position.  This shaft is used on the 1690, 1790, and 2390 device.  The Dor-o-Matic Panic Devices have been around since the late 1960’s, but have most recently been known as the Falcon Panic Device from a name change they had in about 2008.  They are basically the same device, with the same parts, just a different name plate.  The part that the hex key fits into is only about 1/4" deep, because of that these tend to get rounded out, so the key will not move the shaft. 

    To remove the old shaft just pull with a pair of Channel Locks or Pliers.  To reinstall, just press it back in to position, you might have to bend the holding tabs back down, but we very rarely have to do this.  The manufacture part number on this is SHAFT.101.

     

    GPBX16-SHF
  25. Sargent 80 Series Lexan Touch Bar Kit 809

    Sargent 80 Series Lexan Touch Pad Kit

    Sargent 80 series Lexan Touch Pad Kit replaces old and or broken touch pad inserts. On the Sargent part break downs this would be Touch Bar part number 68-0607 and Base 68-0606. The base is 13-1/2" long with 3 mounting holes 4" apart on center.

    Sargent Part # 809 KIT

    G80500
    $83.62
  26. Jackson Panic Device Top Bolt Trip 1085/1285/2086

    The Jackson Panic Device Top Bolt Trip is for use on the 1085, 1285, and 2086 devices.  The 30-824 Trip Assembly mounts on the jamb stop and has a pin that sticks out of it (actually a threaded set screw).  The pin lines up with the release plate on the Top Bolt Guide Assembly, when the pin hits the top plate as the door closes, it releases the rods, so they can extend.

    G108558
    $19.89
  27. Jackson Panic Device 1095 Standard Strike

    The Jackson Panic Device 1095 Standard Strike is a strike they have been using for the past 20 years.  You might have one of the older roller strikes, but this will work in its place.  The older style roller strike is no longer available.  Jackson Exit Device part # 30-2436.

    G109556
    $59.64