Parts
When you purchase panic and exit devices from RBA Door, every product will meet local building codes as well as your expectations for performance and quality. All panic device hardware and accessories are built with durability, convenience and value in mind. No matter the project, our panic devices are a well-built choice at a reasonable price.
-
Dor-o-Matic 1690/1990 Top Strike Shim Package-SHIM.112
Doromatic PB48 Strike Shim Package Of 10 Pieces
This Dor-o-Matic product is for the PB48 Top Strike. This is the shim that goes under the top strike. The plate measures 1" x 1-1/16" with 4 holes. The mounting holes are 11/16" x 11/16" on center. They are only sold in packages of 10.
Doromatic Part # SHIM.112
G199034-SHIM -
Falcon / Doromatic PS914x900-2RS Power Supply
Doromatic PS914x900-2RS Power Supply
Base Power Supply (4A(16A inrush) @12/24 VDC field selectable) with 2 Relay board output. US294 Listed for Access Control, Class 2 rated power limited output. 12" high by 14" wide by 4" deep enclosure.
Related part #'s PS914 and 900-2RS
PS914x900-2RS -
Dor-o-Matic 2390 Lift Bracket BRKT.143 PB336
Doromatic 2390 Lift Bracket
This cadium plated bracket attaches to the concealed vertical rods. When the push bar is depress, it raises and lowers the brackets and the rods. The bracket measures 2-7/8" long by 5/8" wide and has an overall projection of 3/4"
Falcon / Doromatic Part # BRKT.143
GPB336 -
Doromatic 2390 Moving Pushbar End Cap PB342 ECAP.143
Doromatic 2390 Moving Pushbar End Cap
Doromatic 2390 Moving Pushbar End Cap is the piece that fits on the end of the pushbar. The Endcap is 3-3/8" high by 1/4" thick, with an 1-7/8" projection. The Pushbar End Cap is constructed of die cast metal that is painted black.
Doromatic / Falcon Part # PB342 or ECAP.143
GPB342 -
Falcon / Dor-o-Matic 2390 Exit Device
Doromatic 2390 Exit Device
The 2390 is a Grade 1 exit device designed for high use and abuse, and delivers a variety of performance features that ensure smooth, easy and reliable operation. Easier rod adjustment simplifies installation. This device is for replacment of older worn out Falcon / Dor-o-Matic 2390's. This is not a good exit device to use to replace devices from different manufactures.To order specify:Door Width:42" (Device size has a 21" Touchbar)
48" (Device size has a 24" Touchbar)Color:
Aluminum
Dark Bronze
Device Centerline to Finished Floor Measurement in inches:2390EO- -
Dor-o-Matic 1690 Lock Stile Screw PB114
Dor-o-matic 1690 Lock Stile Screw
1/4-20 Phillips Head Screw, a liite less than 1/2" overall lenght.
Doromatic part # SCREW.1069 or PB114
Dor-o-Matic 1690 Repair Parts Breakdown
GPB114 -
Falcon Dor-o-Matic 1590 Latch Bolt Assembly 4270107603
Falcon Dor-o-Matic 1590 Latch Bolt Assembly 4270107603
Replacement Latch Bolt Assembly for the Falcon Dor-o-matic 1590. In the old days you could just replace the PB355 (SPRING.127) spring, but as of November 2015 you have to replace the complete latch head assembly.
Doromatic Part # 4270107603
Old Part # PB124GPB124 -
Falcon Dor-O-Matic STK45 Surface Strike
Falcon Dor-O-Matic STK45 Surface Strike
This strike is used when we have a double door application without a center post. By using this strike we can have one door with a surface vertical rod and one door a rim device, which will save money because vertical rods are usually expensive. This strike can be used with the 1590, 1790 and 2090 Rim Devices. The strike base measures 1-5/16" wide by 3-1/4" high, and 1/4" thick. The three slots are 1-1/4" on center. This strike ships with the mounting screws.
US19-Black finish
STK45 -
Falcon SWITCH.1006 Request to Exit Switch
The Falcon SWITCH.1006 Request to Exit is for use on the Falcon and Dor-O-Matic 1690, 1790 and 2390 devices, produced after June 2002. The Request to Exit Switch allows you to cut the current to various devices when the push bar in depressed.
SWITCH.1006 -
Von Duprin Strike 1409 Blade Stop
The Von Duprin Strike 1409 Blade Stop is used on just about every Von Duprin Rim Device when door frame protection is needed. We see this strike on many Narrow Stile door setups. The strike measures 1-7/8" by 1-3/4" outside dimension. The strike has a projection of 1/2". The strike is constructed die cast metal and the blade is made of stainless steel.
Von Duprin Part # 1409
1409 -
Jackson Panic Device Top Bolt Guide Assembly 1085/1285/2086
The Jackson Panic Device Top Bolt Guide Assembly is used on the 1085, 1285, and 2086 hardware. The piece works by sliding over the top rod when the device is opened. This keeps the rods retracted until the Plunger hits the Trip Assembly when it is closing. Upon hitting the Trip Assy, the plate slides over and the rods retract. It measures 1-1/2” deep x 1-1/16” wide x 15/16” tall, with a hole spacing of 3/4" on the mounting screws. Assembly includes the mounting screws. The Jackson Part number is 30-934.
G108518 -
Jackson Panic Device 1085 And 1095 Dogging Pin
The Jackson Panic Device 1085 And 1095 Dogging Pin is the piece that keeps the hardware in the open position during business hours. It is activated by pressing the crossbar and then turning the flat head screw driver head. The pin is held in the housings with a screw, which is located on the back of the housing. This pin has been used since about 1988 or so, the old style are no longer made, but they had a roll pin that was used to hold it in place. This package comes with a new spring, set screw and the pin. The Jackson part number on this is 30-1115.
G108554 -
Jackson Panic Device Mounting Stud 1085/1095
The Jackson Panic Device Mounting Stud is for use on the 1085 and 1095 panic hardware. Each door would have 2 on the left and 2 on the right, so a total of 4 studs per door. The housings fit over these studs and are held in place by an 1/8" set screw, there are two of these set screws at the top and one on the bottom. The threaded part has a 1/4-20 thread.G108544 -
Jackson Panic Device Crossbar 1085/1095
The Jackson Panic Device Crossbar is for use on the 1085 and 1095 hardware. The bar is 45" long and can be cut in the field with a chop saw or hack saw. There is a groove the entire length of the bar for added and strength and for the thread forming screws to thread into. The Jackson part number is 30-733-PKG, and it ships with the cross bar screws.
Jackson Part # 30-744PKG or 30744PKG
G108520- -
Jackson Panic Device Center Case 1085/1095
The Jackson Panic Device Center Case 1085/1095 is for use with the 1085 devices for both and left, and the inactive case of the 1095. Case is easily removed by loosening the two 1/8" Allen screws and one on the bottom. Includes everything in the housing. The distance between the mounting studs on this Case is 6-5/16"
Jackson part # 30-982 Right Hand Body and Arm Assembly
Jackson part # 30-983 Left Hand Body and Arm AssemblyHousing Shown in Aluminum
G1085XX -
Jackson Panic Device 1095 Active Housing
The Jackson Panic Device 1095 Active Housing is the working side of the 1095 panic hardware. The housing comes will all the internal parts, including the latch bolt. The distance between the mounting studs on this case is 6-5/16". Jackson part # 30-988 Right Hand Body, and part # 30-989 Left Hand Body
Left Hand Housing shown in the aluminum finish.
G1095xx -
Jackson Panic Device 1095 Standard Strike
The Jackson Panic Device 1095 Standard Strike is a strike they have been using for the past 20 years. You might have one of the older roller strikes, but this will work in its place. The older style roller strike is no longer available. Jackson Exit Device part # 30-2436.
G109556